· Downloads available soon
AIAS - 1500 DXC

SPECIFICATIONS
Model1500XDC
REOS number:3946
Max flow rate:15 gallons or 56.78 liters per minute
Duty Cycle:Twenty-four hours
Used Oil Filters:Two stage coalescing type, 3 micron absolute with 99.86% of free standing or emulsified water removal.
Dimensions:Height:51 in. (129.5 cm.)
Width:14.5 in.(36.8 cm.)
Legnth:47.5 in. (120.6 cm.)
Fuel Inlet
and Outlet:1¼ in. NPT, female
Used oil Inlet:1 in. NPT, female
Weight:Dry: 490 lbs.(222 kg)
Wet:724 lbs. (328 kg)
Op. Pressure:Factory Set at 50 psi(3.44 bar)
Filter Housing:Pressure Tested to 75 psi(5.17 bar)
Relief Valves:Factory set to 70 psi(4.82 bar)
Elec. Consumption:Numerous electrical arrangements are available to satisfy worldwide demands
Crated Shipping:Height:57.5 in.146.05 cm
Width:38 in.96.52 cm
Legnth:64 in. 162.56 cm
Shipping weight: 610 lbs. (277 kg)
F.O.B. Point:Troutville, VA 24175, USA

STANDARD FEATURES:
Primary used oil filter indicator lamp and used oil pump shutdown system.
Secondary used oil filter plugged Indicator lamp and used oil pump shutdown system.
Final filter plugged indicator lamp and main fuel pump shutdown system.
No fuel flow indicator and main fuel pump shutdown system.
Remote audible signal or visual indicator: A relay and connectors are supplied for connecting remote audible or visual devices.
Drain final filter indicator lamp: Alerts the operator when to drain water from the final filter/coalescer assembly.
Main fuel pump circuit overload and reset: Alerts the operator of an overload condition. clearly visible and easily reset.
Used oil pump control switch: Turns the used oil pump off in the event you exhaust your used oil supply, but wish to pump, filter and dehydrate your fuel source.
Percent mix adjuster: Allows adjustment of the percentage of processed used oil to be injected into the fuel system from 1% to 10% infinite.
Control Panel: A control panel is supplied on a six foot (6') umbilical cord which allows wall mounting of the control panel for easy viewing and operation.
LCD Screen: Displays fuel and used oil flows in gallons or liters per minute.
Start and Stop Buttons: Large, clearly marked and colored control buttons for "ON" and "OFF" operation.
Pressure Gauges and Bleed Cocks: Gauges are supplied on the used oil and fuel circuits to monitor system pressures and bleed cocks,simplify air removal, and filter priming.
Differential Pressure Gauges: Gauges are supplied for each filter unit to alert the operator when filter replacement is necessary.
Pumps and Motors: All 1500XDC AIAS are equipped with TEFC motors and heavy duty pumps that have a twenty-four hour duty cycle.
Compact Size: All 1500XDC AIAS measure only 14.5 inch deep, 51 inches high, 47.5 inches long.
Mechanical Flow Meter: A mechanical flow meter in gallons or liters is supplied with a four-digit resettable batch meter and a non resettable totalizer.
"Y" Strainer: supplied to remove large particulate matter from the fuel flow prior to entering the system.
Automatic Air Release Valve: Removes air from the final fuel filter/coalescer assembly.

Contact us today for more information